Nikon SLM Solutions SLM 125 — Technical data
The SLM 125 is the smallest machine in Nikon SLM Solutions' range. A 400 W fibre laser exposes a 125 × 125 × 125 mm build envelope, which can be reduced to 50 × 50 × 50 mm for small powder quantities; the substrate plate can be preheated to 200 °C. This makes the machine attractive for research, material development, dental and medical technology and small tooling inserts, for example in cobalt-chrome, titanium or tool steel 1.2709. At 1.4 m long and with 3 kW connected load, it also fits into laboratories. On the manufacturer's website it is no longer linked in the main menu, but the product page and brochure remain available.
With a used SLM 125, look closely at its history: if reactive materials such as titanium or aluminium were processed, powder residues, filter condition and documented cleaning are especially important. Also clarify laser hours, the condition of the build volume reduction, whether a sieving station is included and how long the manufacturer commits to service and spare parts.
Specifications
Looking for a Nikon SLM Solutions SLM 125?
Currently no machine of this model available — talk to us, we source machines like this regularly.
All information according to manufacturer specifications, errors excepted.